manual
We do the utmost to ensure that the provided informaon is complete and accurate; however, images and
specicaons are subject to change without noce. Visit our website at www.ardaappliances.com
for the latest version of this manual.
- 15 -
Hood doesn’t turn on
No electrical supply
Ensure the plug is connected
Ensure the main switch is
turned ON
Power cord is damaged Call ARDA service
Poor airow
Aluminum grease lters
clogged
Clean the lters and replace
when dry
Charcoal lters clogged
(recirculang mode only)
Replace the charcoal lters
Hood is vibrang Hood is not secured in place
Check the installaon of hood
Tighten mounng screws
Motor running but no airow,
or air comes back into room
Damper blocked
Check outside cap to ensure
that it is clear. Check damper
opens when unit is turned
on. Call installer to check for
blockages or narrowing of the
duct.
Motor stops aer a few
minutes
The hood is installed too near
the cooking surface
The hood must be at least
61cm (24” ) from the stove
Strong cooking smell
Fan speed too low Use one of the higher sengs
Charcoal lters not installed
In recirculang mode, charcoal
lters must be installed
Oil dripping onto stove
Aluminum grease lter
saturated
Wash the aluminum grease
lters
Whirring sound
Something in contact with fan
blade
Call ARDA service
Fan does not work Call ARDA service
Lights do not work,
but fan does
Bulbs have burnt out Replace bulbs
All hood lights go out at once Transformer blown Call ARDA service