User's Manual
ARCXTEND 5.8 GHZ USER MANUAL – R1.0, ISSUE 1
Copyright 2005 Arcwave, Inc. 62
arcwaveTFTPserverIP fwDloadInformation 1 1.3.6.1.4.1.8595.1.14.1 This element sets the IP
address of the TFTP
server that will be used for
firmware download.
IP
Address
Read/W rite Current 0.0.0.0
arcwaveFilename fwDloadInformation 2 1.3.6.1.4.1.8595.1.14.2 This element sets the file
name of the firmware to be
downloaded to the Hub.
255
character
alpha
numeric
string
SnmpAdm
inString
Read/W rite Current N/A
acwaveInitiateFirmWareUpgrade fwDloadInformation 3 1.3.6.1.4.1.8595.1.14.3 This element tells the Hub
to initiate a firmware
upgrade.
1 = true
2 = false
Integer Read/Write Current N/A
realtimemonitorInfo productType 15
fwversionNumber realtimemonitorInfo 1 1.3.6.1.4.1.8595.1.15.1 This element contains the
firmware version number
40 character
alpha
numeric
string
SnmpAdm
inString
Read-Only Current N/A
hwversion realtimemonitorInfo 2 1.3.6.1.4.1.8595.1.15.2 This element contains the
hardware version number
40 character
alpha
numeric
string
SnmpAdm
inString
Read-Only Current N/A
dcelock realtimemonitorInfo 3 1.3.6.1.4.1.8595.1.15.3 This element indicates the
status of the PLL on the
AR300 module.
1 = true
2 = false
Integer Read/Write Current N/A
dslock realtimemonitorInfo 4 1.3.6.1.4.1.8595.1.15.4 This element indicates the
status of the Hub
Transmitter Module.
A”true” will be displayed if
the module is active.
1 = true
2 = false
Integer Read/Write Current N/A
dstxpower realtimemonitorInfo 5 1.3.6.1.4.1.8595.1.15.5 This element contains the
downstream transmit
power out of the Hub
Transmitter Module. (in
dBmv)
0 to 99
Integer Read-Only Current
uslock realtimemonitorInfo 6 1.3.6.1.4.1.8595.1.15.6 This element indicates the
status of the Hub Receiver
Module. A ”true” will be
displayed if the module is
active.
1 = true
2 = false
Integer Read-Only Current N/A
powersupplyvoltage realtimemonitorInfo 7 1.3.6.1.4.1.8595.1.15.7 This element contains the
DC output voltage of the
Hub AC power supply as
read from the Extender
Module.
0 to 30
Integer Read-Only Current N/A
txpowerlevel realtimemonitorInfo 8 1.3.6.1.4.1.8595.1.15.8 This element reports the
approximate upstream
transmit power level of the
0 to 99
Integer Read-Only Current N/A