User's Manual

ARCXTEND 5.8 GHZ USER MANUAL – R1.0, ISSUE 1
Copyright 2005 Arcwave, Inc. 56
Environment Specifications
The environmental specifications for the ARCXtend solution including the AX1455, AX3255 and
associated electrical and mechanical subassemblies are given in Table 7-3 below.
Requirement Specification
Altitude
Operating Low to 10,000 feet
Storage and Transportation Low to 50,000 feet
Ambient Temperature
Operating –40 to +65°C (Includes solar loading)
Storage –60 to +75°C
Humidity
Operating 5 to 100% RH Non-condensing
Storage 5 to 95% RH
Rain
Operating Wind driven rain of 5.8 in/hour at 70 MPH
May not cause a link outage, but can degrade performance)
Survival No requirement
Water immersion No leaks at 15 PSI internal pressure for 10 seconds
Salt Spray Per Specification – Comcast 1000 hrs.
Wind
Operating (Hub): 112 MPH (180km/hr) with 1 inch radial ice
May not cause a link outage, but can degrade performance.
The deviation of the antenna main beam axis should not be
more than 0.3 times the smaller of the two azithumal and
elevation HPBW as a general rule)
Survival (Hub)l: 125 MPH (200km/hr)
No significant loss of alignment after test
Vibration
Operating: 0.001 G
2
/Hz from 5-100 Hz (IEC 60068-2-6)
Survival: 0.01 G
2
/Hz from 5-100 Hz (IEC 60068-2-6)
Shock
Survival: IEC 60068-2-27
Packaged: 4 Ft. drop
Corrosion
Plated Surfaces: ASTM D-2247, ASTM B-117/DIN 75-302
Painted Surfaces: ASTM 117-B (Salt Spray), ASTM D3359, ASTM-D4060
UV Resistance/Stability ASTM G-53/DIN 53-505
Lightning/ESD 20kA IEC 1000-4-5 8/20µs Waveform
Surge Withstand Capability
(Hub)
CAT B3 6kV, 3kA Combination wave on all RF ports
CAT A3 6kV, 200A Ring Wave on DC power Port
CAT B3 6kA Combination wave on 120 Vac Transformer
Input
Table 7-3 Environmental Specifications