Copyright 2005 Arcwave, Inc. 51
DCE Lock: Displays the status of the PLL (Phase Lock Loop) in the
AR300 module. It will display “TRUE” if the Hub if the PLL is
working properly and “FALSE” if it is not.
Transmitter Lock: Displays the status of the Hub wireless transmitter. It will
display “TRUE” if the Hub is tuned to transmit at the
downstream wireless carrier frequency.
Transmitter Power Level: Displays the power level of the Hub wireless transmitter into
the antenna.
Transmitter Temperature: Displays the temperature in degrees Celsius at the surface of
the Hub wireless transmitter module.
Receiver Lock: Displays the status of the Hub wireless receiver. It will
display “TRUE” if the Hub is tuned to receive at the upstream
wireless carrier frequency.
Power Supply Voltage: Displays the DC voltage at the ARCSmart AR300 module. It
indirectly reflects the status of the AC adaptor.
Upstream Power Level: Displays the approximate upstream transmit power level. It is
the upstream transmit power level of the ECM minus 10
dBmV.