User's Manual
ARCXTEND 5.8 GHZ USER MANUAL – R1.0, ISSUE 1
Copyright 2005 Arcwave, Inc. 44
Event Syntax Event
Message Text
Severity Customer
Symptom
Explanation of event
/Corrective Action
What will the
Customer
Experience
AR300 System Lock Lost The Unit has
lost lock in the
Upstream or
Downstream
Critical Modems on
the
ARCXtend
system lose
sync
The transmitter or
receiver module (or
both) has lost lock/
Clear alarms and/or
reset power on unit
& check if condition
goes away
Lost of traffic,
system outage
AR300 Hub Dead The Unit is
dead.
Critical Modems on
the
ARCXtend
system lose
sync
The transmitter or
receiver module or
both stop
communicating with
the control module/
Clear alarms and/or
reset power on unit
& check if condition
goes away
Lost of traffic,
system outage
AR300 Input voltage outside
of tolerance
Voltage level is
either below or
above
tolerance limits
Major This alarm
gets
displayed
The voltage being
supplied to the Unit
is improper/ Check
voltage levels &
clear alarm
No immediate
impact but
could result in
loss of traffic,
system outage.
Warning: The Hub is
operating within 10C of its
maximum operating
temperature.
The Unit is
operating near
its maximum
operating
temperature
Major This alarm
gets
displayed
The Unit is operating
near its maximum
operating
temperature. Check
temperature and
clear alarm. If
problem persists
consider adding a
sun shield to unit.
No immediate
impact but
could result in
loss of traffic,
system outage.
AR300 DCE Unlocked or
Error
The Control
module has
lost lock
Critical Modems on
the
ARCXtend
system lose
sync
The Control module
has lost lock/ Clear
alarms and/or reset
power on unit &
check if condition
goes away
Lost of traffic,
system outage
AR300 Upstream (Receiver)
Unlocked or Error"
The Upstream
module has
lost lock.
Critical Modems on
the
ARCXtend
system lose
sync
The Upstream
module has lost lock/
Clear alarms and/or
reset power on unit
& check if condition
goes away
Lost of traffic,
system outage
AR300
Downstream(Transmitter)
Unlocked or Error
The
Downstream
module has
lost lock.
Critical Modems on
the
ARCXtend
system lose
sync
The Downstream
module has lost lock/
Clear alarms and/or
reset power on unit
& check if condition
goes away
Lost of traffic,
system outage
Local Parameter
Modification Notification
There has
been a change
in the
parameters on
the control
module
Normal A change in
parameters is
made via CLI
or by the
control
module
There has been a
change in the
parameters on the
control module/ Do
nothing - it's an
informative alarm
No impact,
informational
only. Note
changes made
via CLI may be
reset upon
reboot of unit.