User's Manual
ARCXTEND 5.8 GHZ USER MANUAL – R1.0, ISSUE 1
Copyright 2005 Arcwave, Inc. 33
between CPE and cable modem or add
amplification.
Redo the CPE alignment process
Verify the wireless range and LOS path
between Hub and CPE are within specified
limits.
Table 4-4: US transmit power level troubleshooting
If the cable modem doesn’t register with the network
If the cable modem does not register with the network, troubleshoot as follows:
Problem Solution
Does not detect and lock on DS channel Check to see if the MER of the downstream
RF channel is within specificied limits:
MER should be at or above 27 dB for 64
QAM, and 31 dB for 256 QAM. If it is not,
check the following:
Verify that the Select Downstream Power
setting is correct for the downstream
modulation and wireless range.
Change Downstream Air Frequency to a
different channel to rule out interference.
Verify the wireless range and LOS path
between Hub and CPE are within specified
limits.
Does not detect and lock on US channel Using the cable modem’s diagnostic
interface, see if the cable modem is seeing
the correct upstream RF channel.
If it does see the channel and can’t lock on,
reduce the Upstream Attenuation setting at
the Hub.
If it does not see the channel, and Cable
Interface Control and Automatic Frequency
Set are enabled, verify that the Hub ECM and
the subscriber cable modem are assigned to
the same upstream frequency and are
excluded from an upstream load balancing
group.