User's Manual
ARCXTEND 5.8 GHZ USER MANUAL – R1.0, ISSUE 1
Copyright 2005 Arcwave, Inc. 29
)Mount a CATV system standard grounding device in Figure 4-4 as close as possible to the
point of cable entry into the building. Connect the grounding device to a suitable “grounding
electrode” as required per local building codes.
3
)Connect the RG-6 coaxial cable from the CPE to the grounding device and waterproof all
outdoor F connectors.
To Subscriber Transceiver
Grounding device
Ground wire (green or bare)
To power inserter
& cable modem
Figure 4-4: Grounding device at subscriber premises
)Inside the subscriber premises, route the RG-6 from the building entrance point to where the
cable modem will be used.
)Terminate and install an F connector on the cable. Connect the cable from the CPE to the
“RF + PWR” F female connector of the power inserter.
Install the power adaptor and DC inserter
)Install the DC inserter as show in Figure 4-5. Connect the power adaptor to the DC inserter
as show in Figure 4-3 and figure 4-5. Plug the power adaptor into a surge protected AC
power receptacle. Note the AC Power Pack must be within 300 feet of the CPE.
3
The National Electric Code, sections 820-33 and 820-40, describes this requirement in detail.