User's Manual

ARCXTEND 5.8 GHZ USER MANUAL – R1.0, ISSUE 1
Copyright 2005 Arcwave, Inc. 28
Figure 4-3: CPE Wiring Diagram
)Connect an RG-6 coaxial cable to the F connector located on the rear of the CPE.
Waterproof the connection using a suitable method such as taping with Coax-Seal
2
or
Scotch #88.
Note: Be sure to leave sufficient cable slack for final CPE alignment and ensure that the cable
runs directly downward from the connector to avoid water running down the cable and into the F
connection.
)Route the coaxial cable to the building entry point utilizing UV-resistant tie-wraps and
staples or cable clamps as required.
Note: UV-rated cable should be used outdoors. In some buildings plenum-rated or riser-rated
cable is required for inside runs.