User's Manual
ARCXTEND 5.8 GHZ USER MANUAL – R1.0, ISSUE 1
Copyright 2005 Arcwave, Inc. 26
Set up and verify the Hub’s wireless interface
)Referring to the Arcwave MIB page of the user interface:
• Set the Downstream Air Frequency.
• Set Select Downstream Power level the appropriate setting:
a. High for use with AX1455-SM-90, AX1455-SM-60, and AX1455-VM-90 Model
Hubs operating with 64 QAM downstream modulation and links greater than
¼ mile.
b. Medium for use with all model Hubs operating with 256 QAM downstream
modulation and 64 QAM modulation with links less than or equal to ¼ mile.
c. Low for use with all model Hubs at links less than 500 feet.
Note: The “High” power setting is for use with the AX1455-SM-90, AX1455-SM-60 and AX1455-
VM-90 Network Hubs. Use of the “High” power setting with the AX1455-SM-25 cancels the FCC
certification and voids the user’s authority to operate the unit in the 5.8 GHz band.
• Verify that Downstream Enable and Upstream Enable are set to true.
If the Cable Interface Control is enabled and the ECM is operational, the Upstream
Attenuation level is set automatically based on the upstream transmit power level of the
ECM. If the ECM is not operation, then the Upstream Attenuation level must be set
manually. A good starting point is 30 dB.
• Verify that Downstream Lock and Upstream Lock are set to true.
Set the Hub Management Mode
)Referring to the Administration table on the Maintenance page and Arcwave MIB page of
the user interface:
1. Enter Title, if desired, otherwise it defaults to the MAC address of the ECM.
2. Choose the method for managing the Hub by setting the Select Control Mode:
• If Control via HTTP is chosen, then the Hub can be managed remotely over the
cable network or locally using the Ethernet port and the HTTP-based user
interface.
• If the Control via SNMP is chosen, then the Hub can be managed remotely over
the cable network using SNMP.
3. Set the Alarm Destination IP address, id desired.
CPE installation
)Install the mounting hardawre (e.g. non-penetrating roof mount, eaves mount) and wiring
per the manufacturer’s recommended procedures and in accordance with the National
Electric Code and local ordinances.