User's Manual
-50
-40
-30
-20
-10
0
10
20
30
40
435
440
445
450
455
460
465
470
475
480
485
Ref Level :
40.0 dBmV
dB / Div :
10.0 dB
Spectrum Analyzer
GOOD
Model: MS2711B Serial #: 00215050
Date: 05/23/2002 Time: 11:55:01
RBW: 1 MHz VBW: 30 kHz Detection: Average
CF: 459.0 MHz SPAN: 50.0 MHz Attenuation: 0 dB
dBmV
Frequency (434.0 - 484.0 MHz)
Figure 2-7: Proper Downstream IF input to subscriber’s modem.
The spectrum analyzer settings for Figure 2-7 are shown in Table 2-1:
Table 2-1: Typical spectrum analyzer settings.
Parameter Setting
Center Frequency 459 MHz
Span 50 MHz
RBW 1 MHz
VBW 30 kHz
Vertical Scale linear, 10 dB / division
Reference Level +40 dBmV
Attenuation 20 dB
Detection Mode Averaging
Align the subscriber Transceiver antenna as described above, adjusting for
maximum signal amplitude.
2.2 Cable Connection and Grounding
Attach the single RG-6 coaxial cable to the F connector on the rear of the Subscriber
Transceiver. See Figure 2-8. Waterproof the connection using a suitable method
such as taping with Scotch #88. Be sure to leave sufficient slack to allow the
ARCXtend manual, August 2003 2-6