User's Manual

DAxxxx Downstream Air MHz
Ax AGC control
Vcddd DAC Output
M[reg][data] MT control
AR250DX[01]>b
Digital Cable Extender Copyright (c) 2003 Arcwave, Inc.
Software Build Aug 13 2003 20:50:47
DCE CATV Input US Channel 0 ( 0 MHz)
DA Air Output 0 MHz (250->150 IF 0 MHz LO: 44 MHz)
........
........
........
AR250DX[01]>dce
? Value 1
? Valid CATV Input Channels are 23-94 and 100-138
AR250DX[01]>dce23
Initializing...
MT2050 Write Reg 0x01 Data 0xAD
MT2050 Write Reg 0x02 Data 0x1C
MT2050 Write Reg 0x03 Data 0xA8
MT2050 Write Reg 0x04 Data 0x00
MT2050 Write Reg 0x05 Data 0x63
MT2050 Write Reg 0x06 Data 0x10
MT2050 Write Reg 0x08 Data 0x29
MT2050 Write Reg 0x0A Data 0x05
MT2050 Write Reg 0x0F Data 0x0F
MT2050 Write Reg 0x10 Data 0x24
DCE CATV Input US Channel 23 (219 MHz)
AR250DX[01]>da
? Value 1
ARCXtend manual, August 2003 4-18