Arcwave Alarm Descriptions
Line
# Alarm Syntax Alarm Message Text
A
larm
Severity Customer Symptom Explanation of event / Corrective Action
What will the Customer
Experience
1
AR300 System Lock Lost
The Unit has lost lock in the
Upstream or Downstream Critical
Modems on the ARCXtend
system lose sync
Clear alarms and/or reset power on unit & check if
condition goes away Lost of traffic, system outage
2
AR300 Hub Dead The Unit is dead. Critical
Modems on the ARCXtend
system lose sync
The transmitter or receiver module or both stop
communicating with the control module/ Clear alarms
and/or reset power on unit & check if condition goes away Lost of traffic, system outage
3
AR300 Input voltage outside of
tolerance
Voltage level is either below or
above tolerance limits Major This alarm gets displayed
The voltage being supplied to the Unit is improper/ Check
voltage levels & clear alarm
No immediate impact but could result
in loss of traffic, system outage.
4
AR300 Downstream
(Transmitter) Over
Temperature
The Unit is operating above Max.
operating temperature Major This alarm gets displayed
The Unit is operating above Max. operating temperature/
Check operating temperature, clear alarm & switch the
unit off if condition does not go away.
No immediate impact but could result
in loss of traffic, system outage.
5
AR300 DCE Unlocked or Error The Control module has lost lock Critical
Modems on the ARCXtend
system lose sync
The Control module has lost lock/ Clear alarms and/or
reset power on unit & check if condition goes away Lost of traffic, system outage
6
AR300 Upstream (Receiver)
Unlocked or Error" The Upstream module has lost lock. Critical
Modems on the ARCXtend
system lose sync
The Upstream module has lost lock/ Clear alarms and/or
reset power on unit & check if condition goes away Lost of traffic, system outage
7
Downstream(Transmitter)
Unlocked or Error
The Downstream module has lost
lock. Critical
Modems on the ARCXtend
system lose sync
The Downstream module has lost lock/ Clear alarms
and/or reset power on unit & check if condition goes away Lost of traffic, system outage
8
Local Parameter Modification
Notification
There has been a change in the
parameters on the control module Normal
A change in parameters is
made via CLI or by the
control module
There has been a change in the parameters on the
control module/ Do nothing - it's an informative alarm
No impact, informational only. Note
changes made via CLI may be reset
upon reboot of unit.
Table A-2 Arcwave Alarm Definitions