User's Manual
ARCXTEND USER MANUAL – R1.4, ISSUE 4
Copyright 2005 Arcwave, Inc. 69
dstxpower realtimemonitorInfo 5 1.3.6.1.4.1.8595.1.15.5 This element contains the
downstream transmit
power out of the Hub
Transmitter Module. (in
dBmv)
0 to 99 Integer Read-Only Current
uslock realtimemonitorInfo 6 1.3.6.1.4.1.8595.1.15.6 This element indicates the
status of the Hub Receiver
Module. A ”true” will be
displayed if the module is
active.
1 = true
2 = false
Integer Read-Only Current
powersupplyvoltage realtimemonitorInfo 7 1.3.6.1.4.1.8595.1.15.7 This element contains the
DC output voltage of the
Hub AC power supply as
read from the Extender
Module.
0 to 30 Integer Read-Only Current
txpowerlevel realtimemonitorInfo 8 1.3.6.1.4.1.8595.1.15.8 This element reports the
approximate upstream
transmit power level of the
hub. Its value is the
upstream transmit power
level of the ECM- 10). (in
dBmv)
0 to 99 Integer Read-Only Current
transmittertemp realtimemonitorInfo 9 1.3.6.1.4.1.8595.1.15.9 This element contains the
temperature at the surface
of the Hub transmitter
module in degrees Celsius.
-40 to 99 Integer Read-Only Current
Table A-1 Arcwave MIB Definitions and OID