User's Manual

ARCXTEND USER MANUAL – R1.4, ISSUE 4
Copyright 2005 Arcwave, Inc. 51
Bit 0: 1 = System Lock Lost
Bit 1: 1 = Hub Dead
Bit 2: 1 = Input voltage outside of tolerance
Bit 3: 1 = Downstream (Transmitter) Over Temperature
Bit 4: 1 = DCE Unlocked or Error
Bit 5: 1 = Upstream (Receiver) Unlocked or Error
Bit 6: 1 = Downstream (Transmitter) Unlocked or Error
Bit 7: 1 = Local modification notification
Alarm Destination Enter the IP address where SNMP traps are to be sent by the
Hub.
Clear Alarms Click on the “Apply” button to clear all alarms. (presented in
the “Event Logs” page)
Real time monitor Click on the “Apply” button to refresh the Real Time Monitor
display.
Burst Override Mode Chose “On” to disable PureBurst and “Off” to enable
PureBurst. When no traffic is present on the upstream cable
interface, PureBurst mutes the interface preventing the
introduction of ingress noise into the cable network.
Firmware Download Information
ARCXtend Id Displays the Hub type, AX1255 or AX1455. This parameter is
used internally by ARCSmart to customize the user interface
based on the Hub type.
TFTP server IP Address Enter the TFTP (Trivial File Transfer Protocol) server’s IP
address.
Firmware Upgrade Filename Enter the file name of the ARCSmart controller firmware to be
downloaded to the Hub.
Start Upgrade Click the “Apply” button to initiate the download. The
download of the new controller firmware will take up to two
minutes. The download can be verified by refreshing the
page. The version number of the downloaded firmware should
be displayed in the Firmware Version Number box under in
the Real Time Monitor Information table.
Arcwave MIB Real Time Monitor Information
Firmware Version Number: Displays the ARCSmart firmware version number.
Hardware Version Number: Displays the ARCSmart AX300 module hardware revision
number.
DCE Lock: Displays the status of the Hub cable network interface in the
downstream direction. It will display “TRUE” if the Hub is