User's Manual
ARCXTEND USER MANUAL – R1.4, ISSUE 4
Copyright 2005 Arcwave, Inc. 49
“Disable” to turn it off. This parameter is useful when the Hub
is used for a non-DOCSIS application, such as the wireless
transport of a digital video or CBR (constant bit rate) voice
signal, and there is no DOCSIS channel on the cable plant.
Selecting the “Off” setting will prevent the ECM from
continually scanning for a downstream channel, when none is
present. The default setting is “On”
Select Upstream Band Chose which of the two copies of the upstream wireless
carrier being transmitted by the CPE is to be received by the
Hub and passed to the cable network. This parameter is used
to avoid potential interference on the upstream channel.
If High is chosen, then the Hub will receive the upstream
wireless carrier at 5300 MHz plus the frequency of the
upstream channel
If Low is chosen, then the Hub will receive the upstream
wireless carrier at 5300 MHz minus the frequency of the
upstream channel.
For example, if the upstream frequency is 32.0 MHz, the
wireless signal will be transmitted at 5332 MHz (High) and
5268 MHz (Low). As show in Table 5-2, certain combinations
of downstream wireless carrier frequencies and upstream
channels require a specific High or Low setting for optimal
performance. For all other downstream wireless carrier
frequencies, the default setting is High.
Auto Frequency Set Chose “ENABLE” to have ARCSmart automatically program
the Hub CATV EIA Input Channel and Upstream Frequency
parameters with the same values used by the ECM. When set
to “ENABLE” these parameters will change whenever the
values are changed at the ECM. This setting is used for plug-
n-play installation of the Hub. Chose “DISABLE” when these
parameters will be set manually to values different than those
used by the ECM. In this mode, the values entered will persist
regardless of the values used by the ECM and across a Hub
power outage or reboot. This mode is useful when the Hub
will transmit a non-DOCSIS channel, such as digital video or
CBR voice.
The default setting is “ENABLE”. Note: “Cable Interface
Control” must be set to “Enable” in order for this element to be
set to “Enable”.
Upstream Frequency Displays the frequency of the upstream channel that is being
received by the Hub.
CATV EIA Input Channel Displays the EIA standard channel number of the downstream
channel that is being received by the Hub.
Upstream Attenuation Chose the amount of attenuation (in dB) in the upstream
receive path of the Hub.