User's Manual
Figure 2-x: Photo of the AR100 Signal Strength Meter (SSM).
Rx SSM LNB
Figure 2-4: AR100 Signal Strength Meter (SSM) at transceiver.
Complete the subscriber physical installation (at least the Subscriber Transceiver and power
inserter). Connect the coax lead from the indoor power inserter to the SSM "RX" port and a short
coax jumper from the SSM "LNB" port to the Transceiver. The SSM and the Transceiver will then
be powered from the power inserter
4
. Align the Transceiver by peaking the signal on the SSM's
meter, adjusting the sensitivity control on the SSM as needed.
Note that the AR100 SSM is a very broadband device which responds to energy below 500 MHz. It
will “see” all energy from few hundred MHz to at least 1900 MHz, and thus can be spoofed by a
stray signal near the Transceiver and SSM.
4
The external power jack on the SSM is unused.
June 2003 Page 2-4