User's Manual

1
12 dB
Tap
W-CMTS
Downstream port
Network port
Upstream port
12 dB
Tap
Upconverter
Upstream IF
from
Hub Transceiver
Downstream IF to
Hub Transceiver
Ups tream p ort is typical
of 1 to 6
100BaseT to/from
Ethernet Switch
and ISP/Internet
ARCi Station
Controller
(future)
Pos (+)
Transc eiver
Telemetry
(future)
Bond Ground
Bus to Rack
DC Voltage
Sense
(+) (-)
DC Power Supply
Remote V. Sense
DC Power to
Hub Transceivers
Neg (-)
Bond Ground Bus
to Facility Ground
NOTE: All Grounds to be bonded
with # 6 AWG or greater stranded
wire, or with ground strap of
eq uivalent cross section area.
Bond Ground Bus
to all ARCi
Transceivers and
Mounting Structures
Ground Bus
1
2
34
Lightning Protector
Reference -
See Page E11
Figure 5-9: Connection diagram of indoor equipment.
5.3.1 Grounding and Lightning Protection
Proper grounding is critical to the safety, performance and the life of the equipment installed at
the base station. Refer to Figure 5-9. Arcwave recommends that the installer follow the general
grounding practices employed in cellular and PCS base station sites.
Arcwave recommends the following Lightning Protectors from PolyPhaser Corp.
(www.polyphaser.com
). These PolyPhaser devices are designed to bolt directly to the ground
bus. See diagram in Figure 5-9 for circled reference numbers.
June 2003 Page 5-9