User's Manual

6. All up converters (CADCO's) to be labeled: “511 MHz – Sectors 1,3,5”
7. A key to sector number and approximate compass direction is to be posted: “Sector 1 –
N, Sector 2 – NE, etc.”
8. A complete single line diagram is to be furnished showing every component of the base
station, including equipment, power cables, signal cables and grounding. Labels on the
diagram must match exactly the physical labels on the actual equipment and cabling.
9. After system turn-up and a small number of pilot subscriber installations are complete
and active, spectrum analyzer traces must be captured and included in the system
documentation package.
a. All downstream 12 dB tap points (upconverter outputs)
b. All upstream 12 dB tap points (upstream input to the W-CMTS)
c. All upstream inputs to the W-CMTS (requires taking the sector out of service for
the trace capture)
June 2003 Page 6-4