User's Manual

March 1, 2002 Page F3
Subscriber Installation Detail
Installation Detail – Subscriber Outdoor Unit
Mounting
Mount the ARCi subscriber outdoor unit (ODU) on a vertical pipe with at least 12 inches clear of
any hardware or other impediments. The mounting brackets will accommodate pipe diameter
from 1.25 to 2 inches. Up-tilt or down-tilt is accomplished by loosening the cap screws on the
sides of the mounting assembly. See Figures F1 and F2. The front face of the antenna must
point in the direction of the system hub and have a clear view of the hub antenna
1
.
Figure F1 Subscriber ODU Orientation
1
Subscriber installations located close to the hub installation may work successfully through nearby tree
foliage, but this must be verified in the field.
Point center of ODU
towards System Hub
Fi
g
ure F2
Subscriber ODU Mounting