PORTABLE AIR CONDITIONER USER MANUAL FOR MODEL: AP6018 Before using your air conditioner, please read this manual carefully and keep it for future reference, along with your receipt.
N Foreword F O R E w O R D * C O N T E N T S Portable Air conditioners are pieces of high value. In order to ensure your lawful rights and interests, please have the professional technicians to do the installation for you. This Instruction Manual is the universal-purpose version for the models of portable air conditioners manufactured by our Co.
PRODUCT DIAGRAM PRODUCT DIAGRAM 1. Control Panel 2. Manual Control Louver & Air Outlet 3. Carry Handle 4. Caster 5. Air Filter 6. Air Filter 7. Hot Air Discharge Opening 8. Air Intake Grille 9. Condensation Drain Hole 10. Exhaust Hose 11. Exhaust Hose Connector 12. Window Kit Adapter 13. Window Kit Panels 14. Wing Nuts 15. Optional Drain Tube 16. Drain Tube Stopper 17. Remote Control 18. Batteries 19. Optional Window Security Pack 20.
PARTS & ASSEMBLY WINDOW VENTING KIT Window Kit Adapter OPTIONAL WINDOW SECURITY BRACKET ASSEMBLY & INSTALLATION When the unit is operating in air conditioning mode, the unit draws in indoor air and exhausts hot air out of the room to complete the air exchange. The Window Kit must be installed when operating the unit in Air Conditioning or Dehumidification Mode. When the unit is operating in Fan Mode, no outdoor air exchange takes place.
WINDOW KIT ASSEMBLY .
WINDOW KIT INSTALLATION PORTABLE AIR CONDITIONER The window venting kit must be installed in order for the unit to work correctly. The window venting kit has been designed to fit into most vertical and horizontal window openings and sliding glass doors up to 7 feet. 1. Open the window or door to adjust the length of the Window Kit Panels to fit the opening. If necessary, mark the kit and cut one end down to properly fit the opening. 2.
SECURITY BRACKET Optional Security Bracket Installation Your Window Kit also includes an optional security bracket that can be installed to prevent the window from being opened from the outside while a Window Kit is installed.
CONTROL PANEL Fan Mode Indicator Air Conditioner Mode Indicator Sleep Mode Indicator Fan Speed Indicators Turbo Cool Indicator Bucket Full Indicator Timer Indicator Power Indicator Dehumidifier Mode Indicator Auto Mode Indicator OPERATING INSTRUCTIONS FOR CONTROL PANEL BUTTONS 1) Power On and Off - Press the POWER button once to manually turn the unit on. Press the POWER button once more to turn the unit off.
REMOTE CONTROL LCD DISPLAY POWER BUTTON TIMER/TEMP INCREASE MODE BUTTON TIMER/TEMP DECREASE SLEEP BUTTON TURBO COOL BUTTON FAN SPEED TIMER BUTTON REMOTE LOCK BUTTON °C/°F SWITCH BUTTON MY TEMP BUTTON 7
REMOTE CONTROL 1) Power On and Off - When the unit is plugged in, press the POWER button to turn on the unit. Press the POWER button once more to turn the unit off. When in Cool mode, Auto mode, and Sleep mode, the selected temperature will appear on the remote control LCD display. When the unit is in Fan mode or Dry mode, no temperature will be displayed. This shows that tempera-ture selection is not available when the unit is in Fan mode and Dry mode.
UNIT OPERATION Cool Mode 1) 2) 3) 4) 5) Install the exhaust hose and window kit properly (see pages 3&4). Plug the Power Cord into an electrical outlet. Turn on the unit by pressing the POWER button. Press the MODE button until the Cool mode indicator lights up on the control panel display. Press the ▲ or ▼until the desired room temperature appears on the control panel display. The tempera-ture ranges from 61˚F - 88˚F. 6) Select the desired fan speed by pressing the FAN SPEED button.
UNIT OPERATION Auto Mode 1) 2) 3) 4) Install the exhaust hose and window kit properly (see pages 3&4). Plug the Power Cord into an electrical outlet. Turn on the unit by pressing the POWER button. Press the MODE button until the AUTO mode indicator lights up on the control panel display. Auto Mode will operate the unit in Cool mode when the temperature is above 72 degrees, Fan mode when the temperature is below 72 degrees.
MAINTENANCE HOW TO DRAIN THE INTERNAL WATER TANK *You will need a small pan, approximately 1” high to catch the water coming out of the water tank. Once the water tank is empty, the unit will resume operation within a few minutes. 1. Do not move the unit when the water container is full. (Water will spill out) 2. Place a small pan under the condensation drain hole on the bottom side of the unit. 3. Remove the drain plug from the condensation drain hole. The condensate water will drain out automatically. 4.
MAINTENANCE NOTE: Make sure power is off and the power cord is not plugged into an electrical outlet prior to performing any maintenance on the unit Clean or replace filter - If the air filter is blocked with a dust, the airflow volume may reduce. It is recommended to clean the filter once every two weeks or as needed. 1) Remove the filter from the filter compartment on the back of the unit. 2) Wash the air filter by immersing it gently into warm water with a neutral detergent.
TROUBLESHOOTING PROBLEM CAUSE SOLUTION Air conditioner does not power on • Unit is not plugged in • No electric current to outlet • Internal safety device has tripped • Plug unit in.
Distributed by: Perfect Aire, LLC 5401 Dansher Rd. Countryside, IL 60525 844-472-2473 www.arcticwindac.com AW/User_AP6018/12152017 Specification and performance data is subject to change without notice.