Technical data
19
Onzen Technical Guide North American Topside
1.15.7 Program Onzen Seings
e Onzen CP Chlorine Production (Onzen Cycle Duration) seings need to be programmed:
e following steps provide guidance on how to program the Onzen system seings:
Steps to Program Onzen Seings
Step 1. Enter Low Level Seings rough Topside Controller
Hold Filter Cycle key for 20 seconds, until “bL” displays.
Scroll through to “ CP ” by repeatedly pushing the Filter Cycle
key.
e CP Chlorine Production details will be displayed.
Step 2. Onzen CP Chlorine Production Duration – Set CP 4
Use up/down arrow keys to change the CP seing to
“CP 4”.
Note: CP 0 indicates that Onzen is o.
CP 4 (16 Hours) is the suggested seing for Start Up - rst 24 hours.
Following Start Up it is recommended to set Onzen Cycle
Duration between 2-4 hours.
en monitor and adjust according to spa usage and bather load.
Step 3. Exit Low Level Seings
Exit the “low level seing” menu by repeatedly pushing the Filter
Cycle key until the screen resets.
Programming Onzen seings is now complete.
Go to, ‘Conducting Ozone and Sanitizer Production Tests’ and
Conduct an ozone and sanitizer production test. ese tests will
conrm that your Onzen system is producing and delivering ozone
and sanitizer to the spa water.