1.15.3 Program Filtration Cycles/Filtration Duration and Stabilise Spa Water
e system will automatically perform 4 ltration cycles per day, 6 hours apart.
During a ltration cycle, the following sequence is executed:
· Pump 2, Pump 3 (on 3 pump systems) and Blower start at high speed for 1 minute.
· Pump 1 then starts and runs at low speed for the preset number of hours.
· Ozone output is turned on.
To set the ltration cycle duration and number of ltration cycles for a 24 hour period, follow this procedure:
Steps to help Set Filtration Duration and Filtration Cycles & Stabilise Water
Step 1. Set Filter Cycle Duration
Press the Filter Cycle Key.
e Filter Cycle Duration details “Fd” will be displayed “Fd XX” .
Use up/down arrow keys to change the Filter Cycle
Duration.
Fd 00 = no ltration.
Fd 01 = 1 hour cycle.
Fd 02 = 2 hour cycle.
FD 01 is suggested
Press the Filter Cycle Key again to scroll forward.
e Filter Cycle Frequency details will be displayed.
Step 2. Spa Filter Cycle Frequency
e display now shows the number of cycles (FFxx) where “xx” is
the number of lter cycles in a 24 hour period.
Select from 1 cycle to 4 cycles per day using the arrow
keys.
FF 04 is suggested
Press the Filter cycle key to accept it.
Filter cycle key to exit Low Level Seings.
A lter cycle will start immediately.
e Filter Cycle triangular icon will appear on the display when a
lter cycle is on.