Use and Care Manual

10
NOTE:
-Make sure the connection is tight and there is no leak.
-Lead the water hose to the floor drain or a suitable
drainage facility, the drainage facility should be lower
than the drain outlet of the unit.
-Be sure to run the water hose sloping downward to let
the water flow out smoothly.
-When the continuous drain feature is not being used,
remove the drain hose from the outlet.
Water hose
Female
threaede
end
Remove the
plastic cover
by couter-clockwise
rotation.
Operation
NOTE: The pump operation on light blinks at 1Hz when the
pump is operational failure. Please turn off the unit and plug
the power cord out. Check the following things:
Cleaning the filter of the pump.
-Remove the bucket from the unit, take down the pump and
clean the filter of the pump.
-Check that the pump drain hose does not link or block.
-Empty the water of the bucket.
-Reinstall the pump hose if it drops and reinstall the bucket
properly. Turn on the unit. If the error repeats, call for
service.
NOTE: Do not use this operation when the outdoor
temperature is equal to or less than 0°C (32°F), otherwise
water is become ice that will cause the water hose blocked
up and the unit failure. Make sure to empty the bucket once
a week when using the pump draining feature. When the
pump draining feature is not being used, remove the pump
drain hose from the outlet. Press the pump drain hose
outlet in and take the pump drain hose out from it . Make
sure do not let the water in the pump hose drip to the floor.
Filter of the pump
2,Take the pump
drain hose out
1,Press the pump drain
hose outlet in