OPERATOR'S MANUAL

57
Division II - Operation/
Maintenance
Previous Main Table of Contents Section Table of Contents NextPrevious Main Table of Contents Section Table of Contents Next
2. Measure the distance from the floor to the mid-point of each
headlight.
3. Using the measurements obtained in step 2, make horizontal
marks on the aiming surface.
4. Make vertical marks which intersect the horizontal marks on the
aiming surface directly in front of the headlights.
5. Switch on the lights. Make sure the HIGH beam is on. DO NOT
USE LOW BEAM.
6. Observe each headlight beam aim. Proper aim is when the most
intense beam is centered on the vertical mark 5 cm (2 in.) below
the horizontal mark on the aiming surface.
7. Adjust each headlight until correct
aim is obtained by turning the
adjuster clockwise to lower or
counterclockwise to raise the
beam.
Fuses
The fuses are located in a power distri-
bution module in front of the steering
post under the electrical access panel. If there is any type of electrical
system failure, always check the fuses first.
NOTE: To remove the fuse, compress the locking tabs on
either side of the fuse cover and lift out.
2411-566
Electrical Output Terminals
Two output terminals for electrical accessories are located on the
front and rear wiring harnesses. The accessory plug is located on the
front body panel.
Tools
A basic tool kit is provided with the ATV. Maintain the tool kit with
the ATV at all times. The tool kit is located under the seat.
KC0108A
CAUTION
Always replace a blown fuse with a fuse of the same type and
rating. If the new fuse blows after a short period of use, con-
sult an authorized Arctic Cat ATV dealer immediately.
CAUTION
Always use electrical accessories less than 180W.
2012 XC 450 i