Upright Refrigerator & Freezer Service, Installation and Care Manual Please read this manual completely before attempting to install or operate this equipment. Notify carrier of damage! Inspect all components immediately. See page 2.
Service and Installation Manual CONTENTS RECEIVING & INSPECTING EQUIPMENT………………………………………..…………………2 SPECIFICATIONS…………………………………………………….……………………….………3 INSTALLATION………………………………………………………………………….…………..….4 OPERATION………..……………………………………………………………………..……………5 MAINTENANCE……………………………………………………………………….……………….7 WIRING DIAGRAM………………………………………………………………………………….……..9 All rights reserved. Reproduction without written permission is prohibited.
Service and Installation Manual SPECIFICATION MODEL# V/Hz/Ph AWR25 115/60/1 AWF25 115/60/1 STORAGE CAPACITY AMPS Cu-ft 4 25 7 25 HP 1/4 3/4 CHARGE BTU/H OZ 830 11.99 1966 10.
Service and Installation Manual INSTALLATION Location Units represented in this manual are intended for indoor use only. Be sure the location chosen has a floor strong enough to support the total weight of the cabinet and contents. A fully loaded unit can weigh as much as 1500 pounds. For the most efficient refrigeration, be sure to provide good air circulation inside and out. Inside cabinet: Do not pack the units so full that air cannot circulate.
Service and Installation Manual OPERATION Refrigerated cycle Refrigerators: During the refrigeration cycle, the evaporator fans will run continuously unless door is open. 1. Every 6 hours, the unit will turn off and to allow the evaporator coil to defrost. The controller now displays the defrost symbol. When the coil temperature reaches 45° or after 20 minutes of defrost, the unit will turn on again. 2. The factory setting for the temperature range is 41° to 33° F.
Service and Installation Manual 2. MAIN FUNCTIONS 2.1 HOW TO SEE THE SETPOINT 1. Push and immediately release the SET key: the display will show the set point value. 2. Push and immediately release the SET key or wait for 5 seconds to display the sensor value again. 2.2 HOW TO CHANGE THE SETPOINT 1. Hold the SET key for more than 2 seconds to change the set point value. 2. The value of the set point will be displayed and the LED starts blinking. 3. To change the set value push the or key within 10s. 4.
Service and Installation Manual Do not use an abrasive cleaner because it will scratch the paint and plastic and can damage the breaker strips and gaskets. Cleaning the Condenser Coil The condenser coil requires regular cleaning, and is recommended every 90 days. In some instances, you may find that there is a large amount of debris and dust or grease accumulated prior to the 90 day time frame. In these cases the condenser coil should be cleaned every 30 days.
Service and Installation Manual sharp tools or knives to scrape or clean the gasket which could possibly tear the gasket and rip the bellows. Gaskets can easily be replaced and don’t require the use of tools or authorized service technicians. The gaskets are "Dart" style and can be pulled out of the grove in the door and replaced by pressing the new one back into place. Doors/Hinges Over time and with heavy use, door hinges may become loose.
Service and Installation Manual WIRING DIAGRAM MODEL: AWR25 MODEL: AWF25 9
Service and Installation Manual WIRING DIAGRAM MODEL: AWR25 10
Service and Installation Manual WIRING DIAGRAM MODEL: AWF25 11