2.8 Troubleshooting
If, at any time during operation, you detect an odor or taste of gas or
vapor, or if you feel eye or throat irritation, you must leave the con-
taminated environment immediately, and refer to the Trouble Shooting
Guide. If necessary, replace lter as instructed in Section 4.2. Failure to
refer to the Troubleshooting Guide if the user detects an odor or taste
of gas, vapor, feels eye or throat irritation could lead to con-
taminant exposure resulting in serious bodily injury or loss of life.
Problem Possible Cause(s) Solution
Blower unit off Turn blower unit on
Blocked Breathing Tube
Airduct, or Blower
Remove obstruction
Leak in Airduct or Breathing Tube Replace defective Airduct and/or Breathing Tube
Filter clogged Replace filter
Battery charge low Recharge battery
Battery defective Replace battery
Battery not connected Check battery to blower connection
Battery not installed Install battery
Battery not charged Recharge battery
Defective switch Contact ArcOne customer service
Motor defective Contact ArcOne customer service
Check outlet voltage Connect to good 110 Volt outlet
Defective charger Contact ArcOne customer service
Defective battery Contact ArcOne customer service
Battery fails to charge
Reduced/No Airflow
Blower does not turn on