USER INSTRUCTION MANUAL 90X110 Auto-Darkening Filters ® Products Which Improve Quality, Productivity, Safety, and Performance ArcOne® is a Division of A.C.E. International Company TEL: 85 Independence Drive, Taunton, MA 02780, USA 1+(508) 884-9600 • TOLL FREE: +1 800) 223-4685 • FAX: (508) 884-9666 PLEASE VISIT OUR WEbSITE: www.arc1weldsafe.
Table of Contents Page Preparations for Use........................................................................................1 Technical Information / Use .............................................................................1 Limitations of Use ............................................................................................3 Care and Maintenance ....................................................................................4 Spatter Protection................................
Shade Adjustment (refer to Fig. 1 through 4): See Filter Specifications (Table 1) for filter specifications. See CE Shade Selection Guide (Table 2) for recommended shades for arc welding applications. Digital LCD Controlled Variable Filters (Fig. 1): briefly press the Mode button (Fig. 1), the LCD mode will flash to indicate the current setting. Press and hold the + or - button to change the setting. The number will change on LCD. Analog Controlled Variable Filters (Fig.
X-TIG Figure 3a: LCD Readout (4000V, 4500V, 5000V, 5500V, 5130V, 7000V, and 7500V) Figure 3b: LCD Readout (5000VX, 5500VX, 5130VX, 7000VX, and 7500VX) Figure 4: LCD Readout (iDF48) Delay Adjustment and Grind Mode (not on all models) Digital Controlled Filters: briefly press the Mode button (Fig. 1), the LCD mode will flash to indicate the current setting (Fig. 3 or 4). Press and hold the + or - button to change the setting.
Care and Maintenance NOTE: Replacement components must be used in accordance with these instructions. Failure to use ArcOne® replacement components in accordance with these instructions voids certification of this product. Filters: Filters require virtually no maintenance other than periodic cleaning when the lens, solar panel, and/or sensor(s) become dirty or clouded from smoke.
COBRA 04-OP Cobra-911-S Cobra 90X110 shell Auto-Darkening Filter 06-HG 06-HGSb 04-OP Inside Cover Plate (see Table 1)* *Optional Mag Lens, VML-XXX, Where XXX=Diopter number (Not shown) VISION® V-911-S Vision 90 x 110 Shell Inside Cover Plate (see Table 1)* 04-OP Auto-Darkening Filter 06-HGSB 06-HG Optional Mag Lens, VML-XXX, Where XXX=Diopter number (Not shown) -5-
PYTHONTM *Optional Mag Lens, Auto-Darkening Filter Inside Cover Plate (see Table 1)* PYTHON-911-S Python 90 X 110 Shell VML-XXX, Where XXX=Diopter number (Not shown) 06-HGSB 06-HG PYTHON01-911-CP Python 90 X 110 Cover Plate PYTHON01-911-CS Python 90 x 110 Center Section Slots bottom Catch Centering Pin Guide Clip Polycarbonate CENTER SECTION INSTRUCTIONS: COVER PLATE INSTRUCTIONS: Slide A-D filter and Inside Polycarbonate into Filter Holder.
VIPER® 06-HG with 06HGSb (not shown) Viper-911-S Viper 90X110 shell Inside Cover Plate (see Table 1)* 04-OP Auto-darkening Filter Viper 911 CS *Optional Mag Lens, VML-XXX, Where XXX=Diopter number (Not shown) CARRERATM 04-OP Outside Polycarbonate CARRERA SCREW (3X16mm) 02-HG Headgear Assembly (Sweatband Included) CARRERA-911-S Helmet Shell Auto-Darkening Filter Inside V I E W : Cover M A N U Plate AL E XP VIE W (see Table 1)* -7- *Optional Mag Lens, VML-XXX, Where XXX=Diopter number (Not sh
Viewing Area Filter Size ARC Sensing Sensitivity Control Switching Time (seconds) Primary Power iDF48 4608 mm Table 1. Filter Specifications 2 (7.1 sq in) 1000FcF 3290 mm 2 (5.2 sq in) 1500V 4416 mm 2 (6.8 sq in) 2000V 4704 mm 2 (7.3 sq in) 2500V 4704 mm 2 (7.3 sq in) 4000V 3290 mm 2 (5.2 sq in) 4500V 3290 mm2 (5.2 sq in) 90x110 mm 90x110 mm 90x110 mm 90x110 mm 90x110 mm 90x110 mm 90x110 mm 1/10,000 (0.1 msec) 1/10,000 (0.1 msec) 5/10,000 (0.5 msec) 5/10,000 (0.
Table 1. Filter Specifications (cont.) 5130V & 5130VX* 4608 mm2 5500V & 5500VX* 4608 mm2 6000VI4 Filter Size 5000V & 5000VX* 4608 mm2 90x110 mm 90x110 mm Sensitivity Control Switching Time (seconds) Digital: Variable Digital: Variable Viewing Area ARC Sensing Primary Power (7.1 sq in) Two sensors Dark to Light Delay 90x110 mm 90x110 mm 90x110 mm Digital: Variable Analog: Variable Digital: Variable Digital: Variable Two sensors 1/10,000 (0.
Significance of Markings: Welding Filters: Example: 4 / 5-8/9<13 AR M 1/1/1/2 EN379 4 – Light Shade number 5-8 – Dark Shade range 1 9<13 – Dark Shade range 2 (Auto-Variable mode) AR – Manufacturers mark M – Auto Variable 1 – Optical Class 1 – Diffusion of Light Class 1 – Variation in Luminous Transmittance class 2 – Angle Dependency class (This is a new classification of EN379. This marking may not be indicated on older models.
Table 2: Shade Selection Guide CE Shade selection Guide Filter Removal Diagram SERIAL NUMBER Serial Number is located on the top of the filter. SE RI AL N UM BE R Serial Number Slide A-D Filter out from under Retention Spring. ® ArcOne® is a Division of A.C.E. International Company TEL: 85 Independence Drive, Taunton, MA 02780, USA 1+(508) 884-9600 • TOLL FREE: +1 800) 223-4685 • FAX: (508) 884-9666 PLEASE VISIT OUR WEbSITE: www.arc1weldsafe.