User manual

ZyWAN User Manual Configuring the ZyWAN
© 2007 Eurotech Ltd Issue B 66
The Table of Terminal Servers looks like this:
The following fields and options are available and must be set for each configured
Terminal Server configuration:
Field/Option Explanation
IP Port
Enter the IP port number (between 1 and 65535) to be used on
the ZyWAN for incoming TCP/IP connections from a network
client application. The IP address to which the client connects
may be any valid address configured for the ZyWAN on any
interface.
Time to Live
Enter the Time To Live for the connection (in seconds). This is
the maximum time of no activity from the network-connected
client, before the ZyWAN closes the Terminal Server connection.
Duplex
Select the duplex mode for the Terminal Server. This selects a
mode of operation for handling bi-directional communication with
a serial device.
Half Duplex: This mode is designed for simple request-response
networks, especially where serial port sharing with another
Terminal Server may be required. After a request is received
from the network and sent to the serial port, one response is
expected. After the serial port times out or after one response is
received and returned to the network client, the Terminal Server
does not read any more serial data until the next request.