User manual
ZyWAN User Manual Configuring the ZyWAN
© 2007 Eurotech Ltd Issue B 62
Field/Option Explanation
ATDT or DCD: Connect if either ATDT### message is received
or if the Data Carrier Detect (DCD) signal on the serial port is
asserted. If the ATDT message is received, it is compared
against the Matching Dial String in the Host Connection rows to
find which IP address to use for connection. If the DCD is
received, the ZyWAN is connected to the IP address of the first
Host Connection row with an empty field for the Matching Dial
String.
Serial Driver
Select whether to use the Native Linux (ttyS) serial driver, or
the Eurotech Ltd driver which allows for half-duplex RS-485
communication. Presently the Eurotech Ltd driver is not
available.
The Host Connection Table is part of the Terminal Client configuration:
At least one row must be configured in the Host Connection Table for it to work
properly:
Button Explanation
Insert Row#
Each row of the Host Connection Table exists as a set of
properties in a numbered table row within the Terminal Client
configuration. In order to insert a row in the table, enter a
number in the box between 1 and one greater than the highest
number of rows. Then click the Insert Row# button to insert a
blank row. This row must be filled in with all data required.
Note that when adding or deleting rows of a Host Connection
Table, make sure to click the Insert Row# or Delete Row#
buttons within the brown section of the Terminal Client, not the
buttons at the very bottom of the main table.
Delete Row#
In order to delete a row of the Host Connection Table, enter a
number in the box between 1 and the highest number of rows.
Then click the Delete Row# button to delete the row. Once a
row is deleted, it cannot be restored without inserting a row
and entering the data again.