Service manual

Configuring the Transportal Interlock Monitor
4-24 SM-1H1.0002, Rev. 1, July 2009
6. Select the desired MLK unit to display the Main Menu for the unit. See Figure 4-24.
Figure 4-24. Typical MICROLOK II Development System Main Menu
4.4.2. Remotely from a Computer Network Workstation
The MICROLOK II (MLK) Development System (“Dev Tool”) must be loaded onto the
workstation being used. TCP-Com must also be loaded and configured to communicate with the
MLK (Refer to Section 4.4.1.1).
1. Navigate to the NimBUS dashboard (or similar server application showing installed
MLK systems) using Internet Explorer.
2. Right-click on the MLK system of interest and select “Dev Tools” from the popup menu.
See
Figure 4-25.
3. If the “Dev Tool” is installed on the workstation and TCP-Com is configured properly
and activated, “Dev Tools” will launch automatically, connect to the selected MLK
system, and display the “Dev Tool” main menu. If not, verify that TCP-Com is installed,
configured properly for this application, and activated.