Configuring the Transportal Interlock Monitor
SM-1H1.0002, Rev. 1, July 2009 4-1
4. CONFIGURING THE TRANSPORTAL INTERLOCK MONITOR
This section provides detailed instructions for configuring the TransPortal Interlock Monitor
(TIM) for operation. By this time, the unit is presumed to be physically installed, that a working
network connection has been established, and that the unit has been turned on, initialized and is
active. The Communication and System Status LEDs should show “all green” status on the top
panel of the unit.
This section provides guidance on how to perform the following configuration steps:
1. Configuring the M
ICROLOK II controller (MLK) for use with the TIM using the embedded
servlet.
2. Configuring TIM operating parameters using the embedded web server.
3. Configuring SNMP Event Traps using the Microsoft Excel spreadsheet tool.
4.1. Configuring the MICROLOK II for Use with the TransPortal Interlock Monitor
The MLK configuration can be changed using the TIM internal configuration servlet. The
servlet can be accessed locally through the Ethernet jack (typically ETH0) on the TIM or
remotely through the WAN port (typically ETH1), by adding the port and directory information
(typically “:10000/microlok”) to the IP address of the TIM. See Figure 4-1.
Figure 4-1. Typical MICROLOK II Settings and Configuration Servlet