User's Manual
26
S26 Request To Send-to-Clear To Send Delay
This register affects synchronous operation only and applies only when you are using
the &R0 command. This register determines how long the modem waits to turn on the
Clear To Send signal after a Request To Send OFF-to-ON transition in 10 ms
increment. The default value is 1.
Range: 0-255
Default: 1
Units: 0.01 seconds
S29
Bit Value Function
0-4 Mapping to AT*I
5-7 Mapping to AT&U
S30 Inactivity Timer
S30 specifies the length of time (in minutes) that the modem will wait before
disconnecting when no data is sent or received. This function is only applicable to
buffer mode.
Range: 0-255
Default: 0
Units: minutes
S45 Timer to Control Sleep Mode
This command displays the number of seconds of inactivity (no characters sent from
the DTE, no RING) in the off-line command state before the modem places itself into
standby mode. A value of zero prevents standby mode.
Note: If a number between 1 and 4 is entered for this register, it will set the value to 5,
and the inactivity before standby will be 5 s. This is done for compatibility with
previous products which allowed time-outs down to 1 s.
Range: 0, 5-255
Default: 10
S95
Bit Value Function
0,1 Mapping to ATWn
2 Mapping to AT\V
3 Mapping to ATN
4 Mapping to AT*O