User's Manual

12
saved by the last &W command.
Z0 Reset modem and retrieve active configuration profit from stored profit 0.
Z1 Reset modem and retrieve active configuration profit from stored profit 1.
Result Codes:
OK n = 0, 1
ERROR Otherwise
&Cn Data Carrier Detect (DCD) Control
Data carrier detect is a signal from the modem to your computer indicating that the
carrier signal is being received from a remote modem. DCD normally turns off when
the modem no longer detects the carrier signal.
&C0 The state of the carrier from the remote modem is ignored. DCD circuit
is always on.
&C1* DCD turns on when the remote modem's carrier signal is detected, and
off when the carrier signal is not detected.
Result Codes:
OK n = 0, 1
ERROR Otherwise
&Dn DTR Control (Data Terminal Ready)
This command interprets how the modem responds to the state of the DTR signal and
changes to the DTR signal.
&D0 Ignore.
&D1 If the DTR signal is not detected while in online data mode, the modem
enters command mode, issues OK result code, and remains connected.
&D2* If the DTR signal is not detected while in online data mode, the modem
disconnects.
&D3 Monitor DTR signal when an on-to-off transition occurs, the modem
performs a soft reset as if the ATZ command was received.
Result Codes:
OK n = 0, 1, 2, 3
ERROR Otherwise
&Fn Load Factory Settings
This command loads the configuration stored and programmed at the factory. This
operation replaces all of the command options and the S-register settings in the active
configuration with factory values.
&Gn V.22bis Guard Tone Control