Specifications
DV - 520
8
INSTALLATION INSTRUCTIONS
PRECAUTIONS
• This appliance must be installed by a qualified gas installer and the installation must
conform to the installation codes.
• Provide adequate clearance around air openings of the appliance. Never obstruct front
openings.
• Provide adequate clearances for proper operation and servicing of the appliance.
• This appliance must be properly connected to a venting system.
• This gas appliance must not be connected to a chimney serving a separate solid-fuel burning
appliance.
• Do not use this appliance if any part has been under water. Immediately call a qualified
service technician to inspect the appliance and to replace any part of the control system and
any gas control which has been under water.
• Caution: Label all wires prior to disconnection when servicing controls. Wiring errors can
cause improper and dangerous operation.
• Verify proper operation after servicing.
• Do not use substitute materials.
• Do not abuse glass doors by striking or slamming shut.
• Do not use abrasive cleaners.
• Use only approved fireplace glass cleaner for cleaning your glass.
LOCATING GAS FIREPLACE
.
See ALLOWABLE TERMINATION LOCATIONS.
The fireplace may be installed in any location that maintains proper clearances to combustibles,
air conditioning ducts, electrical wiring and plumbing. Select a location that is accessible for
venting See section Allowable Termination Locations listed in this manual. When the appliance
is installed directly on carpeting, vinyl tile or other combustible materials, other than wood
flooring, the appliance must be installed on metal or wood panel extending the full width and
depth of the appliance.
GAS CONNECTIONS
Have your gas supplier or a qualified gas fitter run a gas supply line into the fireplace. The line
must be properly sized and fitted according to the installation codes. Immediately upstream of the
supply connection, the fitter shall provide an accessible manual shut-off valve and a 1/8 NPT
plugged tapping accessible for connection to a test gauge.
CAUTION: The appliance and its individual shutoff valve must be disconnected from the gas
supply piping system during any pressure-testing of that system at test pressures in excess of 1/2
psig (3.5 kPa). The appliance must be isolated from the gas supply piping system by closing its
individual manual shutoff valve during any pressure-testing of the gas supply piping system at test
pressures equal to or less than 1/2 psig (3.5 kPa). Failure to do so will damage the appliance’s gas
valve. Such damage is not covered by the manufacturer’s warranty.