Specifications

DV - 520
12
INSTALLATION INSTRUCTIONS Cont...
VENTING
The appliance will not function without being connected to a proper venting system.
This appliance may only use direct vent system for horizontal terminations supplied by
Archgard, or for vertical terminations supplied by either Archgard, Simpson Dura-Vent direct
vent system (type “GS” series) or with Metal-Fab Inc. direct vent system (type “TDV “ series)
together with Archgard SDA-U adapter (when using Dura-Vent or Metal-Fab).
Chart is for one 90° bend, with 1/4” (7 mm)vertical raise minimum per foot of horizontal length.
For each additional 90° or two 45°, add one foot of vertical height.
Maximum three 90º bends, or equivalent.
Minimum 2 ft (610 mm) straight length between bends.
VENTING ABOVE ROOF OF THE HOUSE USING A VERTICAL TERMINATION
Use Archgard, Simpson “Dura-Vent” or “Metal-fab” listed direct vent systems for all vertical
vent termination applications (through the roof). Do not mix component parts.
Please follow these venting instructions as strictly as possible to obtain the best
performance from the appliance.
NOTE:
ALL DIMENSIONS
SHOWN IN FEET
NOTE:
No Installations are
permitted outside of
this range.
VERTICAL HEIGHT
3
20
10
25
1
HORIZONTAL LENGTH
10