Specifications
DV - 520
10
INSTALLATION INSTRUCTIONS Cont...
MO
SPEED
CONTROL
110F (43ºC) N.O.
THERMAL SNAP
SWITCH
CONVECTION BLOWER
LINE
GROUND
NEUTRAL
SIDE OF GAS
FIREPLACE
120 VAC
white
black
SPEED CONTROL
LINE
GROUND
NEUTRAL
110F (43ºC) N.O. THERMAL
SNAP SWITCH
CONVECTION BLOWER
VENT TERMINATION
1. See ALLOWABLE TERMINATION LOCATIONS (page 12) and establish a suitable vent
termination location.
2. In heavy snowfall areas, make sure vent termination is located where it cannot be blocked by
snow from snowfall or from snow-removal equipment.
3. Locate vent termination away from plants, bushes or any other object near the vent termination
that will interfere or obstruct the air flow around it.
4. DO NOT recess vent termination into walls, sidings or planters.
5. Vent terminations located below 7ft from grade level or anywhere that it can be a burn hazard to
the public, such as patios and balconies, must be protected with an Archgard approved
termination cage (part number C-1)
FAN KIT (OPTIONAL)
WIRING DIAGRAM
ALLOWABLE TERMINATIONS LOCATIONS.
See venting chart for
maximum and minimum
vertical/horizontal
venting configurations.