Specifications
27-DVIM22 15
COMPLETE THE CONVERSION
Turn on the gas and electrical supplies.
Turn on the fireplace so the burner is on
Check for leaks at all connections.
Test inlet and outlet pressure. Visually check pilot flame. Flame should envelope top of the flame sensor and extend forward onto the
burner. To adjust pilot turn the pilot adjustment screw on the control valve clockwise to decrease or counter clockwise to increase pilot
flame.
Turn fireplace off
Affix gas type label to the rating plate label. (Bottom right side, under the door frame of insert on pull chain)
Complete the conversion label and affix to valve assembly plate.
Re-install the burner, brick, logs, embers and door. (per the instructions starting on pg. 19)
I M P O R T A N T
For high altitude installations above 4500 ft (1372 meters), consult local gas distributor or
the authority having jurisdiction for proper de-rating methods.
CONVERT THE GAS VALVE
CONVERSION KIT INSTRUCTIONS, cont.
On the SIT valve, use an Allen key or a slotted screwdriver to remove
and discard the three pressure-regulator mounting screws the pressure
regulator tower and the spring diaphragm assembly.
Install the LP identification label
to the valve (found in kit).
Affix Archgard Manufacturer’s label (part # 303-0128)
in a conspicuous location. We suggest a location
close to the gas control valve.
I M P O R T A N T
Ensure that the rubber gasket is properly positioned and install the new
modulating pressure regulator assembly to the valve using the screws
provided in the conversion package.
W A R N I N G
This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer's instruc-
tions and all applicable codes and requirements of the authority having jurisdiction. If the information in these
instructions is not followed exactly, a fire, explosion or production of carbon monoxide may result causing prop-
erty damage, personal injury or loss of life. The qualified service agency is responsible for the proper installation
of this kit. The installation is not proper and complete until the operation of the appliance is checked as specified
in the manufacturer's instructions supplied with the kit.