Technical specifi cations
T61 Tuner
FM Section
Tuning range  87.5 to 108.0MHz
Frequency steps  50kHz
Presets: total/direct access  30/16
Sensitivity (IHF) for 50dB S/N ratio  typically 3µV
Alternate channel selectivity   better than 60dB
Capture ratio  1.5dB
Frequency response  20Hz–15kHz ±1dB
Ultimate S/N ratio (CCIR) Mono  better than –75dB
Stereo better than –70dB
Total harmonic distortion   (96MHz reference, 22.5kHz deviation at 1kHz)
  Mono  better than 0.1%
  Stereo  better than 0.2%
Channel separation (1kHz)  better than 40dB
Pilot tone suppression  better than 60dB
Output level  700mV at 75kHz deviation
AM Section
Tuning range:  10kHz step  530 to 1710 kHz
  9kHz step  531 to 1602 kHz
Presets 16
Usable sensitivity  typically 30µV
IF rejection  > 36dB
S/N ratio (30% mod., 50mV I/P)  > 38dB
Total harmonic distortion (30% mod., 50mV I/P)  < 3%
Output level  300mV at 70% modulation
Control inputs
IR remote standard  Philips RC-5, 36kHz carrier
IR in signal level  4–15V pk-pk 
Trigger operating voltage  9–15V DC
Trigger in polarity  tip positive
General
Output impedance  220Ω
Minimum recommended load  5kΩ
Power consumption  10VA
Size W x D x H  430 x 290 x 85mm
Weight net  3.8kg 
Weight packed  6.0kg 
Supplied accessories  FM dipole aerial
    AM loop aerial
  mains lead
    CR-389 remote control handset and batteries
E&OE
Continual improvement policy
Arcam has a policy of continual improvement for its products. 
This means that designs and specifi cations are subject to 
change without notice.
NOTE: All specifi cation values are typical unless otherwise 
stated.