User Manual

M O D E L 2 1 7 W D R
O P E R A T O R S M A N U A L
8
2.4 PROGRAMMABLE AND OPERATIONAL FUNCTIONS
SINGLE ENTRY PARAMETERS AND FUNCTIONS
FUNCTION
RANGE
WELD TYPE (PULSED, NON-PULSED, STEP,
TACK, S^3)
SELECTABLE
NUMBER OF LEVELS
1 - 99 LEVELS
START CURRENT
5 - 150 AMPS
PREPURGE
10 - 1000 SECONDS
POSTPURGE
10 - 1000 SECONDS
TRAVEL START DELAY
0.0 - 100 SECONDS
TRAVEL DIRECTION
CW or CCW
MULTI-LEVEL PARAMETERS AND FUNCTIONS
The following parameters and functions can be programmed in each level to change
value during a weld sequence.
DOWN SLOPE
0.0 99.9 SECONDS
LEVEL TIME
0.0 999.9 SECONDS
PRIMARY (HIGH) AMPS*
5 150 AMPS
BACKGROUND (LOW) AMPS
5 150 AMPS
SLOPE TIME
CANNOT EXCEED LEVEL TIME
PRIMARY SPEED (RPM)
0.0 RPM TO WELD HEAD MAX.**
PRIMARY SURFACE SPEED (INCHES PER MINUTE)
CALCULATED
AVERAGE AMPS
CALCULATED
FREQUENCY (Hz.)
CALCULATED
% PRIMARY AMPS
1% 100%
PRIMARY (HIGH) PULSE TIME
0.01 9.99 SECONDS
BACKGROUND (LOW) PULSE TIME
0.01 99.9 SECONDS