2 Installing the Compressor
4
2.2 Orientating the Compressor Outlet for Best Fit
The CKMTA series compressors allow for configuring the outlet port to best suit the
installation position and desired position of the outlet hose or coupling (see Fig 1). It is highly
recommended to spend some time experimenting with different configurations prior to drilling
the four mounting holes.
Figure 1.
The points and figures below outline how to remove the compressor cover in order to
orientate the outlet port.
F Unplug the two motor connectors and remove the four cover bolts (10mm socket).
Figure 2.
REMOVE COVER BOLTS