Installation Guide

Consider that Cloud Connectors can provide
coverage on the oor above and below for multi-
oor installations.
The range will depend on the construction of the
building, especially the material of the oor
separators
If possible, plan for Cloud Connectors on each oor
shifted horizontally to maximize the signal coverage,
as seen in the image.
A large site with many sensors requires multiple
Cloud Connectors to provide good coverage.
Estimate by approximating a circle with a 100 m
(328 ft) radius on the oor plan.
Place subsequent circles with approximately 120 m
(393 ft) spacing.
Cloud Connector
Large site
Cloud Connecto
Small site
Cloud Connector
Multiple oors
One Cloud Connector is often enough to cover a
smaller site.
To estimate if a single Cloud Connector can cover your
entire installation site, we recommend approximating
a circle with a radius of 100 m (328 ft) on the oor
plan to mark the expected coverage for the Cloud
Connector.
Planning the installation
Number of Cloud Connector
The number of Cloud Connectors
needed to cover a typical oce space
depends on the size of the space as
well as the material the walls in the
space are made up of.
For example, concrete will reduce the
coverage area more than thin drywall.
See the following sections for how to plan Cloud
Connectors for dierent types of installation sites.
Number
of
Motion
Sensor
The number of motion sensors
needed depends on the size of the
area that needs to be monitored.
Each sensor can cover up to 1
5
0 sqm
(1
6
00 sqft) if installed at the
maximum height of 3.
6
meters (12 ft)
See step
5
for more details about
installation height and detection area