Datasheet

PRODUCT SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE.
VER.2.8 © 2021 SAF TEHNIKA JSC. ALL RIGHTS RESERVED.
WWW.ARANET.COM
Aranet4
HOME
PRO
Measures carbon dioxide concentration,
temperature, relative humidity, and atmospheric pressure
TDSPC0H3
TDSPC003 (EU)
TDSPC0R3 (RU)
TDSPC0U3 (US,AS)
CO
2
concentration
1
Temperature
Relative humidity
Atmospheric pressure
2
Range
0 - 9999 ppm
0 - 50 °C
0 - 85 %
600 - 1100 hPa
Resolution
1 ppm
0.1 °C
(0.1 °F)
1 %
1 hPa
Accuracy
3
± 30 ppm
± 3 % of reading
4
±0.3 °C
(±0.5 °F)
± 3 %
-2 hPa / +3 hPa
Long term drift
N/A
5
0.03 °C/year
(0.05 °F/year)
0.5 %/year
1 hPa/year
Time constant τ (63 %)
6
100 seconds
10 minutes
TBD
instantaneous
Radio parameters
7
Line of sight range
3 km (1.9 mi)
Supported ISM bands
EU868, RU869
US920, AS923
Transmitter power
14 dBm
Data transmission interval
1, 2, 5 or 10 minutes
Data protection
XXTEA encryption
Compatible base stations
Aranet PRO
General
Ingress protection rating
IP20
Operating temperature
range
0 °C to 50 °C
(32 °F to 122 °F)
Operating relative
humidity range
0% to 85 %
Dimensions
70 x 70 x 24 mm
(2.76 x 2.76 x 0.94 in)
Weight
8
104 g (3.7 oz)
Font height on the display
10 mm
Enclosure material
Polycarbonate
Included in the box
2 AA alkaline batteries,
configuration pin
Bluetooth parameters
Line of sight range
10 m (33 ft)
Transmitter power
4 dBm or -12 dBm
Data transmission interval
1, 2, 5 or 10 minutes
Power
2 AA batteries
Type
Alkaline
9
Lithium
10
TX interval
Battery lifetime at 20 °C (68 °F)
11
1
minute
0.7 years
0.9 years
2
minutes
1.2 years
1.7 years
5
minutes
2.8 years
4.0 years
10
minutes
4.8 years
7.0 years
Compliance
CE
Conformité Européenne
IC
Innovation, Science and Economic
Development Canada
FCC
Federal Communications Commission
(USA)
NB! Aranet4 is not impact resistant. Do not leave the device in the direct sunlight.
1
CO
2
sensor of the device is calibrated at standard atmospheric pressure. CO
2
readings are pressure compensated and comply with the
specifications down to 750 hPa. If the device has to be used at high altitude for a prolonged period of time, manual calibration of the unit should be
performed for optimal performance. It is not intended to use the device higher than 4000 m (13 000 ft) above the sea level.
2
The device measures absolute pressure, i.e., pressure readings are not compensated for an elevation above the sea level.
3
95 % of the sensors measure within these typical limits in equilibrium state at the time of sale. For evaluation of the total measurement error long-
term drift has to be taken into account.
4
CO
2
measurement accuracy is provided for a range 0 5000 ppm, temperature 15 … 35 °C (59 … 95 °F) and relative humidity 0 … 80 %. Accuracy
above 5000 ppm is 10 % of reading, but not guaranteed since it is extrapolated form the calibrated range.
5
If a drift of the CO
2
measurements occurs, calibration feature of the device should be used. Auto calibration mode is utilizing ABC algorithm whereas
Manual calibration mode demands sensor to be exposed to fresh air.
6
Time constant is determined at 1 m/s airflow.
7
Available only for the PRO version of the product.
8
Weight with alkaline Fujitsu Premium LR6G07 AA batteries.
9
Fujitsu Premium LR6G07 AA batteries used for tests and calculations.
10
Energizer Ultimate Lithium L91 AA batteries used for tests and calculations.
11
With the Bluetooth connection disabled. Battery lifetime data has been obtained by mathematical extrapolation and is provided for descriptive
purposes only and is not intended to make or imply any guarantee or warranty.