Instruction Manual

2022-11-09 Aranet NH3 sensor kit
FOR MORE DETAILED INFORMATION ABOUT ARANET PRODUCTS, PLEASE VISIT ARANET.COM, CONTACT YOUR ARANET REPRESENTATIVE OR WRITE TO
INFO@ARANET.COM. PRODUCT SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE.
© 2022 SAF TEHNIKA, JSC. ALL RIGHTS RESERVED.
Visual 2. Connecting the Aranet transmitter with the NH
3
sens or
Aranet 0-10 V transmitter with 24 VDC power supply
DOL 53 NH
3
sensor
Slot no. in the
junction box
Corresponding
wire color
Wire color
1
+VCC
White
+24 V
White
2, 3
GND, INPUT -
Green/yellow
GND
Green/yellow
4
INPUT+
Brown
0 10 V output
Brown
Third step: connect the kit to the mains power cable
Make sure the cable is not connected to the power mains. Unscrew and take off the transmitter’s lid.
Connect the cable to the transmitter as shown in the scheme below.
To ensure high IP protection, the cable must be directly connected to mains power.
After finishing the assembly, tighten the cable glands to ensure water protection.
Screw back the transmitter’s lid.
Connection to mains power
N Neutral
L Live
GND*
*The wire should be clipped at the end.
Visual 3. Connect ing the sens or k it with the m ains power