User's Guide

User Guide 98-2489 Rev AB | 5
Series 5 Water M511 Wall Mount Module User Guide
FCC/IC Label Requirements
The text must be clearly visible after the device is installed, and display the module FCC
and IC ID in the following format:
FCC ID: VIDWMNTLG5
IC: 1023A-WMNTULG5
The following statement must also be clearly visible:
This device complies with part 15 of the
FCC rules. Operation is subject to the
following two conditions:
(1) This device may not cause
harmful interference, and (2) This
device must accept any
interference received, including
interference that may cause
undesired operation
RF Exposure Information
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled
environment. This equipment should be installed and operated with a minimum distance of
20cm between the radiator and your body. This transmitter must not be co-located or
operated in conjunction with any other antenna or transmitter.
Cet équipement est conforme aux limites FCC d'exposition aux radiations définies pour un
environnement non contrôlé. Cet équipement doit être installé et utilisé à une distance
minimale de 20cm entre le radiateur et votre corps. Cet émetteur ne doit pas être co-
implantés ou exploités en conjonction avec une autre antenne ou émetteur.
Electrical Characteristics
Battery:
Battery type: Lithium-Thyonil Chloride
Nominal voltage: 3.6 V
Capacity: 8500 mAh
DC Characteristics:
Operating Voltage Range: 3.0 V - 3.6 V
Typical Sleep Current: 17 uA
Radio Characteristics:
Typical Antenna Gain: 3.5 dBi
Frequency Range: 902 MHz - 928 MHz
Modulation Format: 2FSK, GFSK
Transmit Output Power (typical)
Single Channel Mode: -1.5 dBm
Frequency Hopping Mode: 27 dBm, 24 dBm
Receive sensitivity (typical)