Aquor® Wall Hydrant V1+ IN-WALL OUTDOOR FAUCET SYSTEM FLUSH-MOUNT | ANTI-SIPHON | QUICK-CONNECT | SELF-DRAINING | NON-FREEZE aqu r ® water systems
AQUOR® WALL HYDRANT V1+ HHP-SERIES AQUOR® HOUSE HYDRANT V1: WALL HYDRANT / FREEZELESS SILLCOCK Freezeless quick-connect sillcock for exterior building walls. Instant Water Access No Leaks, No Maintenance Less than a second to connect. Garden hoses can be quickly engaged under full pressure, hassle-free. Water flow starts instantly. The pressure-closed valve minimizes wear and cannot be overtightened, for an extremely long lifespan even with frequent use.
AQUOR® WALL HYDRANT V1+ HHP-SERIES Debris cover 1/2” NPT inlet Weather-proof thermoplastic. Stainless upgrade available. Compatible with any fitting type. Rear valve housing (inlet) Stainless steel. Unscrew to access O-rings. EPDM Gasket Main outlet For weatherproofing. Insert hose connector here. Hose Connector Attach to any hose. Hydrant body Marine-grade stainless steel. Viton® O-Ring Professional-grade reliability. Wedge backplate Viton® O-Rings Professional-grade reliability.
AQUOR® WALL HYDRANT V1+ HHP-SERIES Hydrant Parts Breakdown & Descriptions 9 8 7 1 2 3 4 5 6 Need parts? Spare and replacement parts are readily available for every product we make. contact@aquorwatersystems.com PART DESCRIPTIONS 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. Rear Valve Housing (inlet) Valve Return Spring Hydrant Body O-Ring Main Valve O-Ring Operating Rod Hydrant Body Debris Cover Gasket Wedge Backplate Debris Cover Nut & Bolt Debris Cover aqu r ® water systems 11. 12.
AQUOR® WALL HYDRANT V1+ HHP-SERIES FREEZELESS OUTDOOR FAUCET SYSTEM TOTAL LENGTH Flush-mounted freezeless wall hydrant with quick-coupling connection system. • Allows user to access water instantly by connecting under full water pressure. • Robust O-ring connection system ensures a reliable leak-proof seal, even at high water pressures. • Stainless steel operating rod and pressure-closed valve provide zero-maintenance reliability for years.
AQUOR® WALL HYDRANT V1+ HHP-SERIES HHP-002 CLOSE-COUPLE HYDRANT V1+ Inlet: 1/2” NPT 5° 3-7/16” (88mm) Vertical clearance needed with 5° tilt: 1-9/16” (40mm) Horizontal clearance: 1-1/2” (38mm) Stem length: 2” Total installed depth: 3-5/8” (92mm) 4-3/16” (107mm) Use #10 SS screws for mounting Using a 1.5” hole saw is suggested. aqu r ® water systems 2-13/16” [72mm] 3-7/16” [88mm] 1-1/2” [38mm] 3-1/8” [79mm] 2-13/16” [72mm] AQUOR WATER SYSTEMS, INC. - www.aquorwatersystems.
AQUOR® WALL HYDRANT V1+ HHP-SERIES HHP-004 4” HYDRANT V1+ Inlet: 1/2” NPT 3-7/16” (88mm) Vertical clearance needed with 5° tilt: 1-9/16” (40mm) 5° Horizontal clearance: 1-7/8” (47mm) Stem length: 4” Total installed depth: 5-3/4” (138mm) 6-1/4” (159mm) Use #10 SS screws for mounting Using a 1.5” hole saw is suggested. aqu r ® water systems 2-13/16” [72mm] 3-7/16” [88mm] 1-1/2” [38mm] 3-1/8” [79mm] 2-13/16” [72mm] AQUOR WATER SYSTEMS, INC. - www.aquorwatersystems.
AQUOR® WALL HYDRANT V1+ HHP-SERIES HHP-006 6” HYDRANT V1+ 5° 3-7/16” (88mm) Vertical clearance needed with 5° tilt: 1-9/16” (40mm) Inlet: 1/2” NPT Horizontal clearance: 1-7/8” (47mm) Stem length: 6” Total installed depth: 7-3/4” (188mm) 8-3/16” (209mm) Use #10 SS screws for mounting Using a 1.5” hole saw is suggested. aqu r ® water systems 2-13/16” [72mm] 3-7/16” [88mm] 1-1/2” [38mm] 3-1/8” [79mm] 2-13/16” [72mm] AQUOR WATER SYSTEMS, INC. - www.aquorwatersystems.
AQUOR® WALL HYDRANT V1+ HHP-SERIES HHP-008 8” HYDRANT V1+ Inlet: 1/2” NPT 3-7/16” (88mm) Vertical clearance needed with 5° tilt: 1-9/16” (40mm) 5° Horizontal clearance: 1-7/8” (47mm) Stem length: 8” Total installed depth: 9-3/4” (237mm) 10-3/16” (259mm) Use #10 SS screws for mounting Using a 1.5” hole saw is suggested. aqu r ® water systems 2-13/16” [72mm] 3-7/16” [88mm] 1-1/2” [38mm] 3-1/8” [79mm] 2-13/16” [72mm] AQUOR WATER SYSTEMS, INC. - www.aquorwatersystems.
AQUOR® WALL HYDRANT V1+ HHP-SERIES HHP-010 Inlet: 1/2” NPT Vertical clearance needed with 5° tilt: 1-9/16” (40mm) 5° Stem length: 10” 3-7/16” (88mm) 10” HYDRANT V1+ Horizontal clearance: 1-7/8” (47mm) Total installed depth: 11-3/4” (287mm) 12-3/16” (309mm) Use #10 SS screws for mounting Using a 1.5” hole saw is suggested. aqu r ® water systems 2-13/16” [72mm] 3-7/16” [88mm] 1-1/2” [38mm] 3-1/8” [79mm] 2-13/16” [72mm] AQUOR WATER SYSTEMS, INC. - www.aquorwatersystems.
AQUOR® WALL HYDRANT V1+ HHP-SERIES HHP-012 Inlet: 1/2” NPT Vertical clearance needed with 5° tilt: 1-9/16” (40mm) 5° 3-7/16” (88mm) 12” HYDRANT V1+ Horizontal clearance: 1-7/8” (47mm) Stem length: 12” Total installed depth: 13-3/4” (337mm) 14-1/8” (359mm) Use #10 SS screws for mounting Using a 1.5” hole saw is suggested. aqu r ® water systems 2-13/16” [72mm] 3-7/16” [88mm] 1-1/2” [38mm] 3-1/8” [79mm] 2-13/16” [72mm] AQUOR WATER SYSTEMS, INC. - www.aquorwatersystems.
AQUOR® WALL HYDRANT V1+ HHP-SERIES The Aquor House Hydrant is designed for outdoor use. Install in exterior walls of homes and buildings. A small amount of water self-drains from the outlet upon disconnection. The House Hydrant is for heated and insulated building walls only. The House Hydrant can only offer freeze protection if the ambient temperature around the rear valve is above freezing. Mount the hydrant on a flat, level surface that allows the hydrant faceplate to sit tightly against the wall.
AQUOR® WALL HYDRANT V1+ HHP-SERIES Attach the Aquor® hose connector to any garden hose. It can stay attached; there is no need to remove it every use. Before storage, de-pressurize your hose by squeezing the nozzle on the other end. Use any accessory as you would with a traditional bibb. Inline ball valves, timers, splitters, vacuum breakers, and etc. can be attached to the connector. The hose connector has a built-in atmospheric vacuum breaker to prevent any reverse flow or siphonage of liquids.
AQUOR® WALL HYDRANT V1+ Care & Maintenance It’s best to disconnect the hydrant when not in use. The hydrant can only offer freeze protection when disconnected. We recommend unplugging after each use. If you leave the Aquor connector attached to your garden hose, make sure to de-pressurize the hose after use. Temperature changes can cause water inside to expand, causing excessive pressure on the connector’s inernal check valve (and your nozzle or accessories) over time.