ELEKTRA® UV E/ES-Series Ultraviolet Sanitizer/Clarifier System INSTALLATION INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS WARNING FOR YOUR SAFETY — This product should be installed by a professional service technician or similar person, qualified in electrical equipment installation. Improper installation and/or operation could cause serious injury, property damage or death. Improper installation and/or operation will void the limited warranty.
INSTRUCTIONS PERTAINING TO RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSON WARNING — When using this unit, basic precautions should always be taken, including the following: 1. READ AND FOLLOW ALL INSTRUCTIONS. 2. DANGER: To reduce the risk of injury, do not permit children to use this unit unless they are closely supervised at all times. 3. Use this unit only for its intended use as described in this manual. Do not use attachments not recommended by the manufacturer. 4.
SAVE THESE INSTRUCTIONS INSTALLATION INSTRUCTIONS WARNING When using electrical products, basic precautions should always be followed, including the following: 1. DANGER: RISK OF ELECTRIC SHOCK. Connect only to a circuit protected by a Ground Fault Circuit Interrupter. 2. Grounding is required. The unit should be installed and grounded by a qualified service representative. 3. Install to permit access for servicing. IMPORTANT: Follow the instructions EXACTLY and IN THE ORDER LISTED.
8.0 9.0 10.0 11.0 12.0 13.0 14.0 15.0 16.0 17.0 18.0 19.0 7.3 Remove Plastic Electrical Tee Fitting 7.4 Cleaning Quartz Tube 7.5 Re-installing Quartz Tube Assembly UV Bulb Removal/Replacement 8.1 Electrical Connector Assembly Removal 8.2 Removing The UV Bulb 8.3 Removing the Bulb Cushion and O-Rings 8.4 Install Acorn Nut 8.5 Check For Leaks UV Bulb Installation 9.1 Seating Bulb End Cushion 9.2 Installing O-Rings On Bulb End 9.3 Connecting Bulb Pins To Bulb Connector 9.
0.0 Forward: The Elektra® UV Unit is designed for use in swimming pools, fountains, water features, waterfalls and fish ponds. It is not designed for use in potable (drinking) water installations. Use of this product in applications other than those indicated above will void your warranty and could be harmful to your health or the health of others. 1.
are in doubt). If the pump output exceeds the maximum flow rate of the EUV unit you have selected, select an EUV model with a higher flow rate capacity rating or consider a multiple unit installation. (See Sec. 17.7). 3.0 Desired UV Unit Flow Rates Swimming Pools, Fountains, Water Features Delta UV E/ES Model Maximum Flow Rate (GPM) Maximum Flow Rate (LPM) Minimum UV Microwatts sec/cm2 Max Volume 2 Hr. Turnover (Gallons) Max Volume 2 Hr. Turnover (Liters) Max Volume 3 Hr.
5.3 Installing Inlet/Outlet Unions - The EUV unit comes with union nuts installed on the housing. Packed with your EUV unit are the remaining components necessary to complete the Inlet/Outlet unions. The clear union tail piece is used on the top union, and the solid color union tail piece is used on the bottom union. Also packed with your EUV unit are two white gaskets that are used to complete the Inlet/Outlet unions. One side of the gasket is flat, the other side has a half round bead on the face.
5.6 Gluing Piping To The UV Unit - The Inlet/Outlet PVC union tail pieces are 2 inch pipe size (63mm for overseas models). Your PVC supply piping should be glued into the union tail pieces using an appropriate PVC primer and PVC cement, as recommended by your supplier. Inlet piping should be supported and should not rest solely upon the unions, to avoid breaking the unions. The installation of valves on the inlet and outlet lines attached to the UV unit is recommended.
6.0 Start-Up - Once you have completed all the preceeding steps, (IMPORTANT) verification that the unit has no leaks anywhere, including a possible broken quartz tube damaged during transit, you are ready to start your unit up. 6.1 Start Up Circulation Pump - Once the pump is on, be sure to drain all air from your system through the air relief valve on the filter, if so equipped. 6.
7.6 Remove The Quartz Tube - First make sure the quartz tube is cool. Do not handle a quartz tube until it cools. Grasp the quartz tube that is extended above the mounting gland and pull straight up to remove it from the EUV unit wet chamber. The quartz tube can now be easily cleaned. 7.7 Cleaning The Quartz Tube - The quartz tube exterior can normally be cleaned by mixing a mild solution of Muriatic Acid (available at all pool supply stores) with water in a ratio of four parts water to one part acid.
9.3 Connecting Bulb Pins To Bulb Connector - Slowly lower the bulb down into the quartz tube until the bulb O’Rings are down inside the quartz tube. Make sure the bulb O’Rings have not become dislodged from the white ceramic on the end of the bulb while the bulb is being inserted down into the quartz tube. Reposition the bulb O’Rings if necessary. 9.4 Inserting Bulb Into Quartz Tube - CAUTION: DO NOT INSTALL THE ELECTRICAL SOCKET FROM THE BALLAST TO THE FOUR PINS ON THE END OF THE BULB AT THIS TIME.
10.3 Remove Electrical Enclosure Bonnet - Follow Sec. 7.3 instructions to remove the electrical enclosure bonnet. 10.4 Remove The Bulb - Follow the steps noted for bulb removal and replacement during quartz tube removal (Sec. 7.0) and installation (Sec 9.0) to remove the old bulb and complete the installation of a new bulb. 11.
14.0 Swimming Pool Chemicals – Your EUV unit does not add any chemicals to your swimming pool or pond water. Its job is to kill bacteria, parasites, microorganisms and algae that come into contact with the UV rays inside the EUV unit’s wet tank.
17.2 Do I Need To Turn My EUV Unit Off When I Clean My Filter? - No, the flow sensing pressure switch that is part of your EUV unit will automatically shut the UV bulb off until proper water flow inside the EUV unit is re-established. Should you need to turn your unit off for any reason, this is accomplished by simply unplugging the EUV unit from its power outlet. 17.
b. The bulb has become disconnected from the bulb connector. Disconnect the power cord from the electrical outlet, open the electrical enclosure bonnet and confirm the bulb connector is firmly in place. At the same time, check all exposed wires for a possible loose connection. Plug the electrical cord back into the electrical outlet ONLY after the electrical enclosure bonnet has been re-installed on the EUV unit. c. Verify that the electrical cord is plugged into a hot outlet. Test the electrical outlet.
e. If your EUV unit is installed on a swimming pool, shock the pool with the sanitizing chemical you normally use and balance the pool water as per your chemical manufacturers specifications. 18.5 The GFCI Has Tripped - The GFCI protects the system from any fault to ground, as the electrical breaker protects the electrical circuit. When it trips, it is an indication that there is an electrical problem that must be corrected to provide a safe operating environment in your pool or pond. a.
ELEKTRA® UV LIMITED WARRANTY 3 Year - 2 Year Delta Ultraviolet Corporation warrants to every original Purchaser of Delta UV’s Elektra® Series Ultraviolet Unit, that the product will be free from defects, as defined herein, for a period of either three (3) years - (ES-Series) or two (2) years - (E-Series).
REFERENCE INFORMATION DEALER _____________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ PHONE ______________________________________________ CONTACT ____________________________________________ DATE OF INSTALLATION _________________________________ MODEL _________________ RE-LAMP DATE _________________________ RE-LAMP DATE __________________________ RE-LAMP DA
- NOTES - 19
14936 South Figueroa Street Gardena, CA 90248 310-577-1840 PHONE 310-305-9755 FAX CUSTOMERSERVICE@DELTAUV.COM IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS P/N 94-35237 Rev.