Technical data
Electronic scale eliminator ANTICA
++
8
Techical data of EUV xx T.
Water flow
Max. pipe
diameter
Device dimensions
Type
[m
3
/hour
]
[USGAL]
Internal
[mm-
inch]
Ext.
[mm]
[mm] [in]
Input
[VA]
I. 0,.4 -1.4
15.85 - 22.19
EUV 32 T
II. 1.4 -4.4
22.19 - 69.74
32 (5/4")
42 215x130x82
8
7
/
16
x 5
1
/
8
x 3
1
/
4
6
I. 0.8 –2.3
12.68 – 36.45
EUV 40 T
II. 2.3 -6.8
36.45 -107.78
40 (6/4")
48 215x130x82
8
7
/
16
x 5
1
/
8
x 3
1
/
4
6
I. 1.2 –3.5
19 – 55.47
EUV 50 T
II. 3.5 -
10.5
55.47 -166.42
50 (2") 60 215x130x82
8
7
/
16
x 5
1
/
8
x 3
1
/
4
6
I. 2.2 – 6.0
34.87 -95.1
EUV 65 T
II. 6.0 -
18
95.1 – 285.3
65 (2 1/2")
76 215x130x82
8
7
/
16
x 5
1
/
8
x 3
1
/
4
6
Installation of EUV xx T.
N –numbers of coil windings (see table, page 4)