Technical data

Electronic scale eliminator ANTICA
++
4
For devices EUV xx AI connect to water volume measuring device.
2. From supplied power cable (red), wind on vertical or horizontal straight pipe 2 coils with the
number of turns indicated in Table 1 and the distance between them indicated in Table 2.
Please note that both windings must run in the same direction as shown on the installation
diagrams for each type of the device.
Secure the start and finish of each coil winding with the supplied wire ties to the pipe so
the remaining length of both ends of the remaining power cable (red) are approximately of
the same length.
CAUTION!
Wind coils in numbers and direction shown on page 4, Table 1, with the correct distance
between coils, Table 2, on a straight pipe following the distances from fixtures or tees shown on
Device installation. Follow the recommendation of minimum distance to pipe fittings or tees
from the end of the coils that need to be greater or equal to 3 x OD of the pipe where the coils
are installed. Pay attention to the fact that the minimum distance to other parallel piping
should be 2 x OD minimum.
3. After installing the desired numbers of windings at the correct distance between them,
wound in the same direction, secured with cable ties to the pipe, connect the power cable
(red), to the plugs on the Device. There is no preference as to the polarization, hence it is
not designated which end is plugged into the device’s connectors. However pay attention to
piping material, “Metal” or “Plastic” on devices EUV DOM, D, T as the proper function of the
device is dependent on the type of pipe material on which the coils are installed.
4. Plug the device into an electrical wall outlet. All control LEAD lights on the device will light-
up.
5. Program the timers as indicated in the manual for devices EUV xx T and TI.
6. For EUV xx MI and TI program the water meter in accordance with the side panel of the
device.
7. Change the setting to position „A“ for EUV xx AI device.
Checking the function of AntiCa
++
device
Considering the fact that AntiCa++ devices change only the physical properties of the treated
water (formation of aragonite crystals), the functioning of the device can be determined
indirectly. If the water hardness upstream and downstream of the installed AntiCa
++
device is
the same as it is downstream of the protected equipment (hot-water heater, exchanger, etc.),
no scaling of the equipment takes place.
When the device is installed on older systems that were not protected and scaling has already
taken place, then during system de-scaling the hardness of exiting water may be higher than the
initial hardness of water entering the system, indicating de-scaling is taking place. It is possible
to estimate the intensity of system de-scaling from the difference in hardness of systems outlet
and outlet of AntiCa
++
device. It is possible to regulate the rate of the system cleaning process
by changing the level of the AntiCa
++
device output signal.
If the water hardness exiting the system is lower than that measured after the AntiCa
++
device,
sedimentation in the system has occurred and cleaning of the system must be scheduled.
In cases where the AntiCa
++
device is installed on an electric hot water boiler that was not
protected before and has been in use for some time, the boiler must be de-scaled before the
AntiCa
++
device is installed. If de-scaling is not done before installing the device the softened
scale may fall down from the boiler’s wall and damage the heating elements.
Operation and maintenance of AntiCa
++
devices.
The devices do not require any special operation or maintenance. Operations consist of
routine checking of LED lights, which indicate the functioning of the device. If one of
the
LED lights is OFF, it may indicate power failure or that the device is not plugged in or that the
device is faulty. In the case of a faulty device contact the manufacturer or his representative.