Technical data
Electronic scale eliminator ANTICA
++
14
Technical data of AntiCa
++
devices
Power 120 VACV, 50-60 Hz
Room temperature +1 to + 50°C
Pipe surface temperature
EUV xx Dom max. 70 °C
Other types max.150 °C
Length of power coil cable
(red)
max 1,5 m
Length of power cord
EUV xx Dom max 1,5 m
Other types max 2,2 m
Weight EUV
EUV 15 - 25 Dom 0,5 kg
EUV 32 - 65 Dom
EUV 15 - 80 D
1 kg
EUV 32 – 65 T 2,5kg
EUV xx MI, TI AI from 5 kg and above
Input EUV
2 – 16 VA depending on type
of device
EUV 15 - 50 Dom 2 VA
EUV 65 - 65 Dom
EUV 10 – 50 D
5 VA
EUV 65 - 80 D
EUV 32 T – 65 T
6 VA
EUV 50 – 100 MI, TI, AI 8 VA
EUV 125 – 300 MI, TI, AI 10 VA
EUV 400 – 500 MI, TI, AI 16 VA
Contact signal functions
Load on contact relay: 15 W (ohm load, max 1A)
Max voltage at terminals: 125 V
Pulsation current sensor
transmitter
Input voltage 8,2 V DC ( z EUV xx AI )
Reflection power < 1 ,2 mA
Power without refection > 2,1 mA
Constant DN 50 – DN 125 1 impulse / litre
Constant DN 150 – DN 300 1 impulse / 10 litres
Constant DN 300 – DN 500 1 impulse / 100 litres
Digital volume counting
sensor
Specify sensor’s characteristic
Current without flow 0 mA ( 4 mA )
Current at max. flow 20 mA