CAUSE: CORRECTION:
A Water leaks from faucet spouts Adjust the faucet by turning the tee bar located under
the handle to provide a small amount of free play in
the handle when shut off. Should this not work, repair
or replace the faucet.
B Water leaks from beneath the handle Repair or replace the faucet.
6. Faucet leaks or drips
CAUSE: CORRECTION:
A Water is shut off at stop valve Open main stop valve.
B Flowlok is set to off position Make sure Flowlok main lever is in open position.
Lever should be lowered.
C Output line is crimped Reroute the line so they are not restricting the water
from existing the faucet.
D Tank is not pre-charged Empty out the tank and recharge the tank pressure
E Tank is defective or does not hold pressure Replace the tank
F Tank is not lled with water yet Allow holding tank to rell for about an hour or so
before using the water.
G Insufcient water pressure Incoming water pressure must be above 40 psi. Install
a booster pump or permeate pump
H Incorrect installation Check the installation guide and make sure all the
steps are installed properly.
7. Little to no water at dispensing faucet.
CAUSE: CORRECTION:
A Air bubble trapped inside the housing Purge the air by tilting the system on one side, shut
off the tank ball valve and turn on the dispensing
faucet for about 1 minute. Repeat 3 or 4 time to
purge out all the air.
8. System makes humming noise
CAUSE: CORRECTION:
A Insufcient water pressure Incoming water pressure must be above 40 psi. Install
a booster pump or permeate pump
B Lower water temperature Cold water affects the performance of system. Install
a booster pump or permeate pump to compensate for
lower water temperature.
9. Tank takes a long time to ll
CAUSE: CORRECTION:
A Insufcient water pressure for system to shut off Incoming water pressure must be above 40 psi. Install
a booster pump or permeate pump
B Feed water valve is not open fully Open feed water valve fully to lessen the restricted
ow
C Sediment/Carbon pre-lters is clogged Replace the lter
10. System slow to shut off